SDR S2YA05072

Service difficulty report · Pressure Switch · Beech 1900D

Difficulty date
October 31, 2005
Submitted
February 8, 2006
Operation
Air carrier
Aircraft
N87SK
Make and model
Beech 1900D
Aircraft serial
UE87
Engine
Pwa PT6A67D
Part
Pressure Switch
Part number
1143840391
Condition
Inoperative
Location
Bleed Air Sys
Part time
22,889 hours
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON TAKEOFF OF FLIGHT, THE CREW REPORTED THE RT ENVIRONMENTAL BLEED AIR SYSTEM FAILED AND ABORTED THE TAKEOFF. THE SYSTEM WAS PUT ON MEL AND THE AC WAS RETURNED TO SERVICE. REPLACED A BAD PRESSURE SWITCH AND WITH NO FURTHER DISCREPANCIES RETURNED THE AC TO SERVICE. (K)

More about the Beech 1900D