SDR S2YA98019

Service difficulty report · Cam · Beech 1900D

Difficulty date
July 5, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N891SK
Make and model
Beech 1900D
Aircraft serial
UE89
Part
Cam
Part number
10152105223
Condition
Malfunctioned
Location
Rt Te Flap
Stage of operation
TO
Nature of condition
B
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CMH/MKE - FLT 1829 - DURING TAKEOFF ROLL, CREW DETECTED SMELL OF SMOKE AND SAW SMOKE IN CABIN. ABORTED T/O, RETURNED TO GATE. MAINT INSPECTED ACFT, FOUND THE FLAP MOTOR DAMAGED FROM OVERHEATING. FLAP SYSTEM WAS PLACED ON MEL AND ACFT RETURNED TO SERVICE. MAINT REPLACED THE FLAP MOTOR AND FND FLAPS DRIVEN UP AGAINST THE STOPS AND FOUND THE FLAP LIMIT SWITCH CAM PINCH BOLT SHEARED. WHEN CAM BOLT SHEARED, CAM ROTATED OUT OF ALIGN, WHEN CREW HAD SELECTED THE FLAPS UP AT THE END OF PREVIOUS FLIGHT, FLAP MOTOR NEVER SHUT OFF. THIS CAUSED FLAP MOTOR TO OVERHEAT AND FAIL. MAINT REPLACED FLAP MOTOR, ONE FLAP ACTUATOR, AND FLAP LIMIT SWITCH CAM BOX. RIGGED FLAPS, PERFORMED OPER CHK, RETURNED ACFT TO SERVICE. (X)