What was found
MAIN ACCUMULATOR PRESSURE SHOWING "0" AND PUMP OVERRIDE NOT WORKING. COMPLIED WITH ECL HYD PULLED EMERGENCY LANDING HANDLE. R & R HYDRAULIC PUMP, R & R SEPARATION BOLTS. ALL GROUND CHECKED NORMAL, GEAR SWING NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN ACCUMULATOR PRESSURE SHOWING "0" AND PUMP OVERRIDE NOT WORKING. COMPLIED WITH ECL HYD PULLED EMERGENCY LANDING HANDLE. R & R HYDRAULIC PUMP, R & R SEPARATION BOLTS. ALL GROUND CHECKED NORMAL, GEAR SWING NORMAL.