What was found
DURING FLT, RT BLEED AIR LEAK LIGHT ILLUMINATED. CREW COMPLETED QRH 1-6, LIGHT EXTINGUISHED AND FLIGHT CONTINUED. ACFT WAS RETURNED TO HOME BASE USING A FERRY PERMIT. DURING PRELIMINARY INSPECTION FOUND RT BLEED AIR RUBBER DUCT BROKEN. DUCT WAS REPLACED. OPS AND LEAK CHECK PERFORMED FOUND WORKING PROPERLY. ALSO ACFT WAS RELEASED FOR FUNCTIONAL CHECK FLIGHT AND NO ABNORMALITIES FOUND DURING THIS FLIGHT.