What was found
PHL FLT 1190 EN ROUTE PHX TO PHL. CREW RECEIVED AN AVIONICS SMOKE WARNING ON ECAM. THE CREW SELECTED THE VENT BLOWER TO OVER-RIDE. THE WARNING CANCELLED AND THE STATUS PAGE INDICATED VENT BLOWER INOPERATIVE. THE AVIONICS SMOKE WARNING RETURNED AGAIN PRIOR TO ARRIVAL IN PHL. FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE PERFORMED A BITE CHECK OF THE AEVC COMPUTER. NO FAULTS WERE NOTED. OK FOR SERVICE. SUBSEQUENT INFO: MAINTENANCE REPLACED THE AVIONICS EQUIPMENT VENTILATION COMPUTER ON 1/19/07.