What was found
BDL - THE EMERGENCY LIGHT SYSTEM FAULTED WITH -EXT LOAD AFT L- MESSAGE DURING THE EMERGENCY LIGHTS TEST. MAINTENANCE REPLACED THE AFT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BDL - THE EMERGENCY LIGHT SYSTEM FAULTED WITH -EXT LOAD AFT L- MESSAGE DURING THE EMERGENCY LIGHTS TEST. MAINTENANCE REPLACED THE AFT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK.