As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(B-18607)REJECTED TAKEOFF DUE TO FLIGHT CONTROL SYS B LOW PRESSURE LIGHT ILLUMINATED JUST BELOW 80 KNOTS IAW FIM 27-21, TASK 814, FLT CONTROL HYD MODULE SYS B LOW PRESSURE SWITCH CLEANED UP. CHECK LOW PRESSURE LIGHT EXTINGUISHED AND THE RESULT IS NORMAL IAW AMM 05-51-07 HIGH ENERGY STOP INSPECTION RESULT NORMAL IAW AMM 27-09-61. REPLACED THE LOW PRESSURE SWITCH AND OPERATION CHECK RESULT IS NORMAL.