What was found
DURING MAINTENANCE CHECK, CORROSION WAS FOUND AT FUSELAGE LONGERON PLATE LOCATED ON STA 2362 S-23R. THIS AREA ORIGINAL INSP PLAN WAS FOLLOW 53-916-01. THE BLEND OUT SIZE IS 5" X 2.5" WITH MINIMUM REMAINING THICKNESS 0.049". FUSELAGE LONGERON PLATE LOCATED ON STA 2362 S-23R REPAIRED BY EO 744-53-00-0666, RECOMMENDS THAT TO TRIM OUT THE BLEND OUT AREA AND PERFORM A EXTERNAL SPLICE DOUBLER REPAIR PER SR: 4-3500881998,