What was found
(B-18617) ENG 2 EDP LOW PRESSURE LIGHT ON. CK FOUND ENG-2 EDP SHAFT SHEARED AND EDP CASE DRAIN FILTER HAS METAL CONTAMINATION. IAW AMM 29-11-11, REPLACED ENG-2 EDP. IAW AMM 29-11-51 REPLACED CASE DRAIN FILTER ELEMENT; IAW AMM 29-11-61 REPLACE RETURN FILTER ELEMENT; IAW AMM 29-11-71 REPLACED PRESSURE MODULE FILTER ELEMENT. IAW AMM 29-11-00 PFM HYD SYS B FLUSHING. ENG-2 RUN UP CK NO LEAKING WAS FOUND AND OPS TEST OF THE HYD SYS A AND B WAS NORMAL, IAW AMM 29-11-00.