What was found
DURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS ON FLOORBEAM LOWER T-CAP IN THE AFT CARGO COMPARTMENT AT STA 1130, FROM RBL 45 TO LBL 45. REMOVED CORROSION IAW B727 SRM 51-10-06. FABRICATED REPAIR ANGLES FROM BAC 14902685 AND BAC 14982831. TREAT AND PRIME REPAIR PARTS IAW B727 SRM 51-10-02, MM 51-20-02. INSTALLED IAW B727 SRM 51-30-02.