What was found
DURING HEAVY MAINTENANCE INSPECTION, CORROSION WAS FOUND OUT OF LIMITS AT BS 848.95 STRINGER 2L. REMOVED CORROSION IAW B727 SRM 511006. REMOVED DAMAGED SECTION OF STRINGER IAW B727 SRM 531003. FABRICATED REPAIR FROM BAC 1498143, 2024 T3 .250 AND 2024 T3 .090 IAW B727 SRM 531003. TREATED AND PRIMED IAW B727 SRM 511002, MM 512002. INSTALLED IAW B727 SRM 531003, MM 512002.