What was found
DURING HEAVY MAINTENANCE INSPECTION, THE SUPPORT FITTING LOCATED AT BS 940 WAS FOUND GOUGED OUT OF LIMITS. REMOVED GAUGE IAW B727 SRM 511004. PERFORMED EDDY CURRENT INSPECTION. FABRICATED DOUBLER FROM 7075 T6 .071. TREATED AND PRIMED IAW B727 SRM 511002, MM 512002. INSTALLED IAW SRM 513002.