What was found
DURING HEAVY MAINTENANCE INSPECTION THE OXYGEN MANIFOLD AT PSU 4L FAILS LEAK CHECK. REPLACED PSU OXYGEN MANIFOLD PER B727 MM 252131. LEAK CHECK AND OPS CHECK GOOD IAW B727 MM 352100.