What was found
CHANNEL CORRODED AT BS 990 INBD OF R2 DOOR. REMOVED CORROSION ON CHANNEL AND FOUND TO BE OUT OF LIMITS. R & R THE CHANNEL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CHANNEL CORRODED AT BS 990 INBD OF R2 DOOR. REMOVED CORROSION ON CHANNEL AND FOUND TO BE OUT OF LIMITS. R & R THE CHANNEL.