As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND KNOWN CRACK AT R1 DOOR WL 220 UPPER FWD. CORNER STUB FRAME A&1, GALLEY DOOR PANEL. CRACK FOUND ON BEARSTRAP WHILE PERFORMING HIDDEN DAMAGE INSPECTION ON FWD UPPER R1 DOOR FRAME. REMOVED DAMAGE TO BEAR STRAP. ACCOMPLISHED NDT TO VERIFY NO FURTHER DAMAGE. REPAIRED AREA.