What was found
ACCOMPLISH LT INBOARD WING LEADING EDGE FASTENER HOLE DAMAGE REPAIR. REMOVED SKIN DAMAGE. CUT OUT MEASUREMENT 4.250" X 1.250". HFEC INSPECTION REQUIRED. HFEC ACCOMPLISHED ON CUTOUT. NO CRACKS FOUND. FABRICATED REPAIR PARTS. .071" 2024-T3 DOUBLER AND .063" 2024-T3 FILLER. DRILLED AND REAMED FOR FASTENERS. RIVET HOLES ARE .192". !/4 HILOCKS ARE REAMED TO .262" AND 3/16 HILOCKS ARE REAMED TO.199". READY TO PRIME AND INSTALL. ALODINED AND PRIME BOTH DOUBLER AND FILLER. READY TO INSTALL. INSTALLED DOUBLER AND FILLER.