What was found
PASSENGER COMPARTMENT FLOOR BEAM AT STA 986.5 LBL 43.5 CORRODED AT FASTENER HOLE ON TOP FLANGE. REMOVED CORROSION ON THE TOP FLANGE OF FLOORBEAM @ STA 986.5, LBL43.5. ORIGINAL THK .150", REMOVED .020", REMAINING THK .130", FOUND BEYOND ALLOWABLE DAMAGE LIMITS. CUT FLANGE (TOP) OF ENTIRE LENGHT OF FLOORBEAM, FABRICATED, LOCATED, DRILLED AND ISNTALLED FULL LENGHT, UPPER CHORD FLOORBEAM RPEAIR (STA 986.5, LBL 50 - RBL 50).