What was found
RH LE SLAT #7 BARE METAL SHOWING ON UNDERSIDE ALONG AFT EDGE. FOUND TRAILING EDGE WEAR BEYOND REPAIRABLE LIMITS PER SRM 57-42-01-2R-6 REPAIR 6. REMOVED #7 SLAT REF AMM 27-81-21. INSPECTED INTERFACE, OK TO INSTALL. INSTALLED NEW SLAT IAW AMM 27-81-21-400-801. SLAT ACCOMPLISHED TASK 27-81-21-400-801. COMPLETED LEADING EDGE #7 SLAT ADJUSTMENT REF AMM 27-81-00-820-803. FINISHED INSTALLATION AND RIG REF AMM 27-81-00. OK FOR SERVICE. COMPLETED RII OF #7 SLAT INSTALLATION.