What was found
RH LE SLAT #6 BARE METAL SHOWING ON UNDERSIDE ALONG AFT EDGE. FOUND TRAILING EDGE WEAR BEYOND SRM REPAIRABLE LIMITS PER SRM 57-42-01-2R-6 REPAIR 6. REMOVED #6 SLAT REF AMM 27-81-21. PERFORMED INTERFACE INSPECTION AND OK TO INSTALL NEW SLAT. INSTALLED NEW SLAT IAW AMM 27-81-21-400-801. COMPLETED LEADING EDGE #6 SLAT ADJUSTMENT REF AMM 27-81-00-820-803. FINISHED INSTALLATION WITH RIG, REF AMM 27-81-00. OK FOR SERVICE. COMPLETED RII OF #6 SLAT INSTALLATION.