What was found
AFT PAX. CABIN FLOORBEAM CAP AT BS 947.5 CORRODED AROUND FASTNER HOLES AT UPPER AND LOWER SURFACES. FABRICATED REPAIR STRAP FOR STA. 947.5 FLOOR ROOM. ALL WORK DONE IAW B737-800 SRM 51-10-02, SRM 53-70-51 REPAR 6 FIG 204, SRM 51-40-05, AMM 51-21-41 AND AMM 51-21-72.