What was found
CORROSION ON FLOOR SUPPORT STRUCTURE FROM STA 1006 TO STA 1016 , LBL APROX. 20" AND AROUND FASTENER HOLES.REMOVED AND REPLACED FLOOR STRAP ON SUPPORT STRUCTURE FROM STA 1006 TO STA 1016 IAW B737-800 SRM-51-40-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT STRUCTURE FROM STA 1006 TO STA 1016 , LBL APROX. 20" AND AROUND FASTENER HOLES.REMOVED AND REPLACED FLOOR STRAP ON SUPPORT STRUCTURE FROM STA 1006 TO STA 1016 IAW B737-800 SRM-51-40-02