What was found
TOOLING MARKS ON FLOOR BEAM BS 294.5, LBL 11 TO RBL 41. BLENDED ON UPPER SURFACE OF FLOOR BEAM 294.5 AT RBL 24.5 AREA 1.75" L X .7" W X .015" D. FOUND TO BE OUT OF LIMITS, IAW SRM 53-10-51-1A-1 DET C. ALL OTHER BLEND AREAS .012" OR LESS WITHIN LIMITS, IAW SRM 53-10-51-1A-1 DET C. REPAIRED OUT OF LIMIT AREA, IAW SRM 53-10-51-2R-14 WITH 7075T6#0. .100" LOT# 5065468-1. 57828U.