What was found
SEAT TRACK FLOOR STRUCTURE CORRODED AROUND HOLE BS 328 +5", LBL 43. CORROSION FOUND ON SEAT TRACK FLOOR STRUCTURE STA 328+5 LBL 43 FOUND TO BE OUT OF LIMITS, IAW SRM 51-10-02-0G-0 9C. REMOVED AND REPLACED FLOOR STRUCTURE WITH NEW, IAW SRM 51-40-02 AND DWG 141A5730 09/08/2020 57111U PART 141A5770U3.