What was found
TOOLING MARKS ON FLOOR STRUCTURE BS 328 TO BS 344 LBL 11. REMOVED TOOLING MARKS ON FLOOR STRUCTURE STA 328-344 LBL 11 IN AN AREA OF L 2" X W .6" X D .017", IAW SRM 51-10-02-0G-0. DAMAGE FOUND TO BE OUT OF LIMITS, IAW SRM 53-10-51-1A-1 FIGURE 105 DETAIL C. REMOVED AND REPLACED PANEL BREAK STA 328-344 LBL 11, IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0 AND DWG 141A5400 SHEET 29 REV- 57901U.