What was found
TOOLING DAMAGE ON LAV HARD POINT SUPPORT BS 294.5 TO 312 LBL 11.16 WL 208. TOOLING DAMAGE ON LAV HARD POINT SUPPORT BS 294.5-312 LBL 11.16 WL 208 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS, PER SRM. REMOVED AND REPLACED LAV HARD POINT SUPP BS 294.5-312 LBL 11.16 WL 208, IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0 AND DWG 141A5600 SHEET 2 REV N 57901U.