What was found
CORROSION AROUND NUTPLATE ON UNDERSIDE OF FWD CARGO BAY BAFFLE STA 500A+15.5 RBL 25 WL 156. CORROSION ON UNDERSIDE OF BAFFLE FOUND TO BE OUT OF LIMITS, IAW SRM 53-00-53-1A-2 FIG 103 DETAIL DETAIL D. REMOVED BAFFLE, IAW SRM 51-40-02-0G-0. INSTALLED NEW BAFFLE P/O 804719/2, IAW SRM 51-40-02-0G-0 AND BOEING DWG 143A7505 REV D.