What was found
CORROSION FOUND ON NET TIE DOWN @STA. 792, STR. 23L. DUE TO NO ALLOWABLE LIMITS IN THE SRM, TIE DOWN PLATE AT STA. 792 S23L FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FROM 7075T6 0.125 LOT # 5047700. INSTALLED IAW SRM 51-40-02-0G-0, BOEING DWG 146A9401 REV