What was found
CORROSION FOUND IN NUTPLATE @STA. 986.5, LBL 43, WL 208. CORROSION FOUND OUT OF LIMITS @ STA. 986.5, LBL 43 WL 208 PER SRM 53-70-51-1A-1, FIG 104. REPAIRED STA. 986.5 FLOOR BEAM PER SRM 53-70-51-2R-4, FIG 204.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND IN NUTPLATE @STA. 986.5, LBL 43, WL 208. CORROSION FOUND OUT OF LIMITS @ STA. 986.5, LBL 43 WL 208 PER SRM 53-70-51-1A-1, FIG 104. REPAIRED STA. 986.5 FLOOR BEAM PER SRM 53-70-51-2R-4, FIG 204.