As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BLEED TRIP OFF LIGHT ILLUMINATED DURING CLIMB, FAULT CODE 361 012 01. COMPLETED FIM 36-10 TASK 809 AND WAS SWAPPED HIGH STAGE VALVE BETWEEN NR 1 AND NR 2 ENGS IAW 36-11-06/401. INSTALLATION TEST NORMAL. SWAPPED BLEED AIR REGULATOR BETWEEN NR 1 AND NR 2 ENG IAW AMM 36-11-04/401. INSTALLATION TEST NORMAL.