What was found
BIRD STRIKE ON R/H WING L/E FIXED PANEL O/B OF FIXED LANDING LIGHT. DAMAGE L-11", H-9", D 1 3/4" SPEED TAPE APPLIED TO DAMAGED AREA. HISTORICAL WORK: MRO EMP # 3426 - REMOVED AND REPLACED R/H WING FIXED L/E SKIN O/B OF FIXED LANDING LIGHT IAW SRM 51-40-02-OG-0, DWG 116A-4008 REV D. DWG 116A4008 REV. MRO EMP # 3426 - REMOVED AND REPLACED R/H WING FIXED L/E SKIN O/B OF FIXED LANDING LIGHT IAW SRM 51-40-02-OG-0, DWG 116A-4008 REV D. DWG 116A4008 REV -