What was found
WORK ORDER N808SY/2772/B737/H CHECK: - - INITIAL INSPECTION: CORROSION ON PREVIOUS REPAIR OF FLOOR STRUCTURE BEAM, STA= 986.5, STA= 986.5 BTW LBL 32 AND RBL 45 (W2). - - RESOLUTION: FLOOR STRUCTURE BEAM, STA=986.5 BTW LBL 50 AND RBL 50 WAS REPAIRED PER B737-800 SRM 53-70-51-2R-4 REPAIR 4.