What was found
PASSENGER COMPARTMENT FLOOR STRUCTURE AT STA 986.5 BETWEEN RBL 45 AND LBL 45 FLOOR BEAM UPPER CHORD WITH CORROSION IN SEVERAL PLACES. REPAIRED TRANSVERSE FLOORBEAM AT STA 986.5 UPPER CHORT SECTION BETWEEN LBL52 AND RBL52 (SPLICED AT LBL 7.9) IAW SRM 53-70-51-2R-4 REPAIR 4 PARAG 1A PARAG 2 AND PARAG 4 ALTERNATIVE 1 FIGURE 204 NOTE: THIS REPAIR IS A CATEGORY A REPAIR THE INSPECTIONS GIVEN IN THE MPD ARE SUFFICIENT TO MAINTAIN DAMAGE TOLERANCE OF THE INITIAL STRUCTURE SRM REV 83 DATED 11/10/2024