What was found
CATERING TRUCK RAILING MADE CONTACT AFT OF L2 DOOR. REPAIR THE DAMAGE ON FUSELAGE SKIN AT BS 1006 TO 1016 BETWEEN STR 14L TO 15L IAW SRM 53-70-01-2R-5, REPAIR 5, ALTERNATIVE 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CATERING TRUCK RAILING MADE CONTACT AFT OF L2 DOOR. REPAIR THE DAMAGE ON FUSELAGE SKIN AT BS 1006 TO 1016 BETWEEN STR 14L TO 15L IAW SRM 53-70-01-2R-5, REPAIR 5, ALTERNATIVE 3.