What was found
WEAR ON LOWER SETTLEMENT AREA AT VERTICAL STABILIZER ACCESS PANEL NUMBER 323AL STA 1006 TO 1016 ORIGINAL THICKNESS: IS 0.063 IN AND MINIMUM REMAINING THICKNESS: IS 0.030 IN THEREFORE IT'S OUT LIMITS PER B737-800 SRM 55-30-01-1A-2 ALLOWABLE DAMAGE 2 PAR 4.B DETAIL D - - SUMMARY: ANGLE LOWER SETTLEMENT AREA AT VERTICAL STABILIZER ACCESS PANEL NUMBER 323AL STA 1006 TO 1016 WAS REPLACED PER B737-800 SRM 51-40-02-0G-0