What was found
WHITE SMOKE CAME OUT OF APU EXHAUST AFTER SHUT DOWN. REF AML 816815 ITEM 1. WHITE SMOKE CAME OUT OF APU EXHAUST AFTER SHUTDOWN. INSPECTED APU PER FIM 49-95 TASK 801 FOUND SMALL AMOUNT OF OIL FROM AFT DRAIN. FOUND LARGE OIL WETTING ON & AROUND MIDDLE TURBINE BEARING SUPPORT STRUT. PER FIM 49-95 TASK 801 E.1(A) SUGGESTS APU REPLACEMENT. REMOVED AND REPLACED APU RED TASK CARD 490000000. OPS TEST NORMAL. THIS CLEARS MEL 49-1-A MDDR# 140705. - ADDITIONAL: INSPECTED APU PER FIM 49-95 TASK 801 FOUND SMALL AMOUNT OF OIL FROM AFT DRAIN. FOUND LARGE OIL WETTING ON & AROUND MIDDLE TURBINE BEARING SUPPORT STRUT. PER FIM 49-95 TASK 801 E.1(A) SUGGESTS APU REPLACEMENT.