What was found
DURING C-CHECK, FOUND RIGHT WING, FIXED LEADING EDGE UPPER SURFACE AFT OF NUMBER 5 SLAT, WING STATION 436.5 IS CRACKED IN 4 PLACES ALONG RIVET ROW. CRACKS BLEND TOGETHER MEASURING A TOTAL OF 8.25 INCHES LONG, AND 6 RIVET HEADS ARE SHEARED. HIGH FREQUENCY EDDY CURRENT SHOWED NO CRACKS, FABRICATED AND INSTALLED DOUBLER, ANGLE DOUBLER, AND FILLER PER 57-30-04.