What was found
THE EMERGENCY EXIT AREA LIGHT AT SEAT ROW 11 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY IAW MM 33-50-81 AND LIGHT OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE EMERGENCY EXIT AREA LIGHT AT SEAT ROW 11 WAS FOUND TO BE INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY IAW MM 33-50-81 AND LIGHT OPS CHECKED GOOD.