What was found
DURING HEAVY MAINTENANCE VISIT, FOUR HOLES WERE PARTLY DRILLED INTO THE UPPER SURFACE OF A FLOOR BEAM AT BS 360, LBL 6. REMOVED THE DRILL MARKED AREA, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH B727 SRM 53-10-08.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, FOUR HOLES WERE PARTLY DRILLED INTO THE UPPER SURFACE OF A FLOOR BEAM AT BS 360, LBL 6. REMOVED THE DRILL MARKED AREA, FABRICATED AND INSTALLED A REPAIR IN ACCORDANCE WITH B727 SRM 53-10-08.