DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT TIE FITTINGS AND BOLTS IN THE AFT CARGO COMPARTMENT, BODY STATION 1183, RBL 38. REMOVED AND REPLACED FITTINGS IN ACCORDANCE WITH B727 SRM 51-10-1, 51-30-3 AND 51-10-2.