What was found
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR BEAM CHORDS AT BS 1130, RBL 70 AND LBL 70. TRIMMED OUT DAMAGED AREA, FABRICATED AND INSTALLED FILLERS, ANGLES, AND STRAPS IN ACCORDANCE WITH B727 SRM 53-10-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR BEAM CHORDS AT BS 1130, RBL 70 AND LBL 70. TRIMMED OUT DAMAGED AREA, FABRICATED AND INSTALLED FILLERS, ANGLES, AND STRAPS IN ACCORDANCE WITH B727 SRM 53-10-8.