What was found
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT NEXT TO L2 DOOR, BS 1030. REMOVED CORRODED FLOOR SUPPORT, FABRICATED AND INSTALLED A NEW SUPPORT IN ACCORDANCE WITH B727 SRM 51-40-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT NEXT TO L2 DOOR, BS 1030. REMOVED CORRODED FLOOR SUPPORT, FABRICATED AND INSTALLED A NEW SUPPORT IN ACCORDANCE WITH B727 SRM 51-40-4.