What was found
EMERGENCY FLOOR TRACK LIGHTING WAS FOUND INOP AT ROWS 9 THROUGH 16. REMOVED AND REPLACED BATTERY (P/N 5776-1) AND POWER SUPPLY (P/N 5822-14) AND REPLACED EMERGENCY LIGHT TRACK LEAD ASSEMBLY, OPS CHECKED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY FLOOR TRACK LIGHTING WAS FOUND INOP AT ROWS 9 THROUGH 16. REMOVED AND REPLACED BATTERY (P/N 5776-1) AND POWER SUPPLY (P/N 5822-14) AND REPLACED EMERGENCY LIGHT TRACK LEAD ASSEMBLY, OPS CHECKED NORMAL.