What was found
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT UNDER GALLEY AT STATIONS 1030 TO 1070, LBL 15. FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 53-10-01, 51-10-02, 51-30-01 AND 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR SUPPORT UNDER GALLEY AT STATIONS 1030 TO 1070, LBL 15. FABRICATED AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 53-10-01, 51-10-02, 51-30-01 AND 51-10-01.