What was found
DURING HEAVY MAINTENANCE VISIT, THE CABIN FLOOR SUPPORT INTERCOSTAL WAS FOUND CRACKED BETWEEN FRAMES AT STATION 400 TO 420, LBL 5. REMOVED, FABRICATED AND INSTALLED NEW ANGLE IAW B727 SRM 51-20-1, 51-30-2 AND MAINTENANCE MANUAL 51-20-11.