What was found
DURING HEAVY MAINTENANCE VISIT, CABIN FLOORBEAM TOP CAP AT STATION 1090, FROM 4 LBL TO 4 RBL WAS FOUND CORRODED. FABRICATED AND INSTALLED ANGLE AND FILLER REPAIR PER B727 SRM 53-10-8 FIGURE 8 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, CABIN FLOORBEAM TOP CAP AT STATION 1090, FROM 4 LBL TO 4 RBL WAS FOUND CORRODED. FABRICATED AND INSTALLED ANGLE AND FILLER REPAIR PER B727 SRM 53-10-8 FIGURE 8 .