What was found
DURING HEAVY MAINTENANCE VISIT, THE UNDER FLOOR PANEL FOR THE RIGHT FORWARD LAV WAS FOUND CORRODED BEYOND LIMITS AT STATION 312, RBL 44. REMOVED, FABRICATED, AND INSTALLED NEW SUB FLOOR IAW B727 SRM 51-30-2, 53-10-10, AND MM 51-20-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, THE UNDER FLOOR PANEL FOR THE RIGHT FORWARD LAV WAS FOUND CORRODED BEYOND LIMITS AT STATION 312, RBL 44. REMOVED, FABRICATED, AND INSTALLED NEW SUB FLOOR IAW B727 SRM 51-30-2, 53-10-10, AND MM 51-20-11.