What was found
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOORBEAM AT STATION 950F BETWEEN STRINGERS 27 AND 28 LEFT. CUT OUT CORRODED SECTION OF FRAME, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW B727 SRM 53-10-3, 53-10-4, AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, FOUND CORROSION ON FLOORBEAM AT STATION 950F BETWEEN STRINGERS 27 AND 28 LEFT. CUT OUT CORRODED SECTION OF FRAME, FABRICATED AND INSTALLED FILLER AND DOUBLER IAW B727 SRM 53-10-3, 53-10-4, AND 51-30-2.