What was found
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE FLOORBEAM AT STATION 1110, RBL 10. CUT-OUT CORROSION, FABRICATED, AND INSTALLED REPAIR ANGLES AND STRAPS PER B727 SRM 53-10-8 FIGURE 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON THE FLOORBEAM AT STATION 1110, RBL 10. CUT-OUT CORROSION, FABRICATED, AND INSTALLED REPAIR ANGLES AND STRAPS PER B727 SRM 53-10-8 FIGURE 3.