What was found
DURING HEAVY MAINTENANCE VISIT, FOUND FLOOR SUPPORT FRAME CORRODED NEAR L-2 DOOR FLOOR AREA, STATION 1070 LBL 24 TO 65. REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 51-30-2, 51-10-1, 51-20-1 AND MM 51-20-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE VISIT, FOUND FLOOR SUPPORT FRAME CORRODED NEAR L-2 DOOR FLOOR AREA, STATION 1070 LBL 24 TO 65. REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW B727 SRM 51-30-2, 51-10-1, 51-20-1 AND MM 51-20-2.