What was found
DURING HEAVY MAINTENANCE VISIT, FOUND FLOOR BOARD SUPPORT INTERCOSTAL CORRODED BEYOND LIMTS AT FS 344, LBL 30. REMOVED DAMAGED SUPPORT, FABRICATED AND INSTALLED A NEW SUPPORT IN ACCORDANCE WITH SRM 53-10-2, 51-20-1, 51-10-2 AND 51-30-2.